Seren Industrial Power Systems, Inc.                    

 2009 - Standard Products

 R Series - High Frequency RF Generators (1.7 – 40.68 MHz)

Model

Power

Frequency

Cooling

Mounting

H x W x D

R301-13

300 W

13.56 MHz

Air

½ Rack

5.25” x 8” x 19”

R601-13

600 W

13.56 MHz

Air

½ Rack

7” x 8” x 18.5”

R1001-13

1000 W

13.56 MHz

Air

½ Rack

7” x 8” x 18.5”

R1001/1.2

1200 W

13.56 MHz

Water

½ Rack

7” x 8” x 18.5”

R2001-13

2000 W

13.56 MHz

Water

19” Rack

7” x 19” x 23”

R3001-13

3000 W

13.56 MHz

Water

19” Rack

7” x 19” x 23”

R5001-13

5000 W

13.56 MHz

Water

19” Rack

8.75” x 19” x 26.5”

R10,001-13

10,000 W

13.56 MHz

Water

19” Rack

10.5” x 19” x 29.25”

R15,001-13

15,000 W

13.56 MHz

Water

19” Rack

10.5” x 19” x 29.25”

R20,001-13

20,000 W

13.56 MHz

Water

TBD

TBD

Additional Frequencies available – consult your local Seren representative.

 HR Series – High Frequency RF Generators (1.7 – 40.68 MHz)

Model

Power

Frequency

Cooling

Mounting

H x W x D

HR601

600W

13.56 MHz

Water

½ Rack

5.25” x 8” x 19”

HR1001

1000W

13.56 MHz

Water

½ Rack

5.25” x 8” x 19”

HR1501

1500W

13.56 MHz

Water

½ Rack

5.25” x 8” x 19”

HR2001-AC

2000W

13.56 MHz

Air

½ Rack

7” x 8” x 22”

HR2001

2000 W

13.56 MHz

Water

½ Rack

7” x 8” x 22”

HR3001

3000 W

13.56 MHz

Water

½ Rack

7” x 8” x 22”

HR5001

5000 W

13.56 MHz

Water

½ Rack

7” x 8” x 22”

 Additional Frequencies available – consult your local Seren representative.

 L Series - Low Frequency RF Generators (100 – 460 KHz)

Model

Power

Frequency

Cooling

Mounting

H x W x D

L301

300 W

350 -460 KHz

Air

½ Rack

5.25” x 8” x 19”

L601

600 W

350-460 KHz

Air

½ Rack

7” x 8” x 18.5”

L1001

1000 W

350-460 KHz

Air

½ Rack

7” x 8” x 18.5”

L2001

2000 W

350-460 KHz

Water

19” Rack

7” x 19” x 23”

L3001

3000 W

350-460 KHz

Water

19” Rack

7” x 19” x 23”

L5001

5000 W

350-460 KHz

Water

19” Rack

8.75” x 19” x 26.5”

“ L “ Series generators may be purchased in the following bands:

100 – 120 KHz, 200 – 300 KHz, 350 – 460 KHz, 100 – 460 KHz

 AT Series - Automatic matching Networks (1.7 – 40.68 MHz)

Model

Power

Rating

Cooling

Caps.

H x W x D

AT-3

300 W

20 Amps @ 2.5 KV

Air

Air/Air

* 5” X 9” X15”

AT-6/100

600 W

35 Amps @ 4.5 KV

Water

AIr/Vac.

* 5” X 9” X15”

AT-6/500

600 W

35 Amps @ 4.5 KV

Water

Air/Vac.

* 5” X 9” X15”

AT-10

1000 W

50 Amps @ 9 KV

Air

Vac./Vac.

* 6” X 13.2” X 13.4”

AT-20

2000 W

65 Amps @ 9 KV

Water

Vac./Vac.

6” X 13.13” X 13.38”

AT-30

3000 W

75 Amps @ 9 KV

Water

Vac./Vac.

6” X 13.13” X 13.38”

AT-50/120

5000 W

120 Amps @ 6 KV

Water

Vac./Vac.

7.5” X 14.7” X 14.4”

AT-50/140

5000 W

140 Amps @ 6 KV

Water

Vac./Vac.

9.5” X 16.13” X 17”

AT-100/160

10-15KW

160 Amps @ 6KV

Water

Vac./Vac.

Custom

AT150/180

15-20KW

180 Amps @ 6KV

Water

Vac./Vac.

Custom

AT-250/250

15-30KW

250 Amps @ 6KV

Water

Vac./Vac.

Custom

 Note: * AT Series incorporate DC Servo motors with a external Match Controller,

 ATS Series - Automatic matching Networks (1.7 – 40.68 MHz)

Model

Power

Rating

Cooling

Caps.

H x W x D

ATS-3

300 W

20 Amps @ 2.5 KV

Air

Air/Air

* 5” X 9” X15”

ATS-6/100

600 W

35 Amps @ 4.5 KV

Water

AIr/Vac.

* 5” X 9” X15”

ATS-6/500

600 W

35 Amps @ 4.5 KV

Water

Air/Vac.

* 5” X 9” X15”

ATS-10

1000 W

50 Amps @ 9 KV

Air

Vac./Vac.

* 6” X 13.2” X 13.4”

ATS-20

2000 W

65 Amps @ 9 KV

Water

Vac./Vac.

6” X 13.13” X 13.38”

ATS-30

3000 W

75 Amps @ 9 KV

Water

Vac./Vac.

6” X 13.13” X 13.38”

ATS-50/120

5000 W

120 Amps @ 6 KV

Water

Vac./Vac.

7.5” X 14.7” X 14.4”

ATS-50/140

5000 W

140 Amps @ 6 KV

Water

Vac./Vac.

9.5” X 16.13” X 17”

ATS-100/160

10/15KW

160 Amps @ 6KV

Water

Vac./Vac.

Custom

ATS150/180

15-20KW

180 Amps @ 6KV

Water

Vac./Vac.

Custom

ATS250/250

15-30KW

250 Amps @ 6KV

Water

Vac./Vac.

Custom

 Note: ATS Series incorporate Stepper motors with a internal match controller.

 Manual matching Networks

Model

Power

Frequency

Cooling

Mounting

Description

MM300

300W

13,56 MHz

air

N/A

Manual Match

MM600

300W

13,56 MHz

air

N/A

Manual Match

 Matching Networks accessories

Model

Power

Frequency

Cooling

Mounting

Description

MC2

110/220

Volts AC

N/A

Air

External

Match Controller for At Series Match

 

MCRS

110/220

volts AC

N/A

Air

External

Match Remote Control for ATS Series Match

DCP-1

 

3KV

All

N/A

Internal

DC Probe

Match Option

RFP-1

 

3KV

All

N/A

Internal

RF Probe

Match Option

I-Probe

3KV

All

N/A

Internal

Current Probe

Match Option

PD-1

 

All

All

N/A

Internal

Pulse Detector

Match Option

VIP-1

 

TBD

13.56 MHz

N/A

External

Voltage/current Probe

Match Option

LFI-1

 

1KW

350-460kHz

Air

Internal

Second Match Input for Low Frequency, 1KW

LFI-3

 

3KW

350-460 kHz

Air

Internal

Second Match Input for Low Frequency, 3KW

DCIP-1

 

2KW

DC

Air

Internal

Second Match Input for DC, 2KW

 Low Frequency matching Transformers

Model

Power

Frequency

Taps

Description

MT-1U/D-6

1KW

100 – 460 kHz

6

Step Up/Down, 6 Pos.

MT-1U/D-11

1KW

100 – 460 kHz

11

Step Up/Down, 11 Pos.

MT-3U/D-6

3KW

100 – 460 kHz

6

Step Up/Down, 6 Pos.

MT-3U/D-11

3KW

100 – 460 kHz

11

Step Up/Down, 11 Pos.


 Optional Interfaces, Generator and Matching Networks

Model

Power

Frequency

Cooling

Mounting

Description

ProfiBus

All

All

N/A

Internal

Interface

DeviceNet

All

All

N/A

Internal

Interface

EitherNet

All

All

N/A

Internal

Interface

MODBUS

All

All

N/A

Internal

Interface

 

 Common Exciter’s & Phase Shifters

Model

Power

Frequency

Cooling

Mounting

Description

DMO-16

110/220

Volts AC

1-41 MHz

Air

External

Digital Master Oscillator- 16 Chan.

CEX-4

110/220

Volts AC

13.56

air

External

Common Exciter

4 Channel

CEX-6

 

110/220

   Volts AC

13.56

air

External

Common Exciter

6 Channel

PS-1

 

N/A

13.56, 27.12, 40.68 MHz

air

External or Internal

0 – 360 Degree

Phase Shifter

 

 Filters

Model

Power

Frequency

Cooling

Mounting

Description

LPF-600W-1S

 

600W

13.56 MHz

air

EXTERNAL

or Internal

Filter, Low Pass, 600W, N&N Female

LPF-1KW-2S

 

1KW

13.56 MHz

air

EXTERNAL

or Internal

Filter, Low Pass,

1KW, N&N Female

LPF-2KW-2S

 

2KW

13.56 MHz

Air

EXTERNAL

or Internal

Filter, Low Pass,

2KW, HN&HN Female

LPF-3KW-2S

3KW

13.56 MHz

Air

EXTERNAL

or Internal

Filter, Low Pass,

3KW, HN&HN Female

LPF-5KW-2S

 

5KW

13.56 MHz

Air

EXTERNAL

or Internal

Filter, Low Pass,

5KW, Din/Din Female

LPF-10KW-2S

 

10KW

13.56 MHz

Air

EXTERNAL

or Internal

Filter, Low Pass, 10KW, LC&LC Female

BP-27-3KW

 

3KW

27.12 MHz

Air

External

27.12 MHZ Band Pass Filter

RFB-1

 

1-3KW

13.56 MHz

Air

EXTERNAL

or Internal

Passes DC, Blocks RF

 

 General Accessories

Model

Power

Frequency

Cooling

Mounting

Description

RMC

 

110/220

volts AC

N/A

Air

External

Remote Control for HR Series Generator

SB-2W-7A

 

24 VDC

Any

Air

External

2 Way Switch @ 7 Amps.

SB-3W-7A

 

24 VDC

Any

Air

External

3 Way Switch @ 7 Amps.

SB-2W-17A

 

24 VDC

Any

Air

External

2 Way Switch @

17 Amps.

SB-3W-17A

 

24 VDC

Any

Air

External

3 Way Switch @

17 Amps.

 

 RF Coaxial Cables

LMR-400

 

1-2KW

2 to 27.12 MHz

N/A

External

RF Coaxial Cable

RG393

 

1-5KW

2 to 40.68  MHz

N/A

External

RF Coaxial Cable

RG58

 

Signal

2 to 40.68  MHz

N/A

External

RF Coaxial Cable

AVA5-50

 

10-15KW

2 to 40.68  MHz

N/A

External

RF Coaxial Cable